AmetekHaydonKerk AmetekAMS

Size 14 (35000)

Dual Motion Size 14
The Haydon Kerk™ 35000 Series (Size 14) of dual motion actuators are available with a limitless number of operating parameters allowing each device to be custom manufactured according to customer specific application requirements. Linear motion can be optimized based on a variety of lead screw resolutions yielding linear travel ranging from 0.0025mm to 0.04mm per step. Rotary motion is achieved with either 1.8° or 0.9° step angle motors in both single and double stack.
  • Specifications - 1.8° Single Stack (Linear or Rotary) +


    Series
    35H4-V 35H6-V
    Stack Length
    Single Single
    Wiring Units Bipolar Unipolar
    Step Angle degree 1.8° 1.8°
    Winding voltage VDC 2.33  5 12  5  12
    Current/Phase A rms 1.25  0.57  0.24 0.57 0.24 
    Resistance/Phase ohms (Ω) 1.86  8.8  50.5 8.8  50.5
    Inductance/Phase mH 2.8  13  60 6.5  30
    Power Input Watts 5.7 5.7
    Standard motors are Class B rated for a maximum temperature of 130°C (155°C for Class F)

    Linear Travel / Step
    Load Limit
    Order Code I.D.
    inches mm lbs n
    0.00006 0.0015* 30 133 U
    0.000078* 0.00198* 30 133 V
    0.00012 0.0030* 30 133 N
    0.000156259 0.0039* 30 133 P
    0.00024 0.0060* 50 222 K
    0.0003125 0.0079* 50 222 A
    0.00048 0.0121* 50 222 J
    0.0005 0.0127 50 222 3
    0.000625 0.0158* 50 222 B
    0.00096 0.0243* 50 222 Q
    0.00098 0.025 50 222 AQ
    0.00125 0.0317* 50 222 C
    0.00192 0.0487* 50 222 R
    *Values truncated 
  • Specifications - 0.9° Single Stack (Linear or Rotary) +


    Series
    35K4-V 35K6-V
    Stack Length
    Single Single
    Wiring Units Bipolar Unipolar
    Step Angle degree 0.9° 0.9°
    Winding voltage VDC 2.33  5 12  5  12
    Current/Phase A rms 1.25  0.57  0.24 0.57 0.24 
    Resistance/Phase ohms (Ω) 1.86  8.8  50.5 8.8  50.5
    Inductance/Phase mH 2.8  13  60 6.5  30
    Power Input Watts 5.7 5.7
    Standard motors are Class B rated for a maximum temperature of 130°C (155°C for Class F)

    Linear Travel / Step
    Load Limit
    Order Code I.D.
    inches mm lbs n
    0.00006 0.0015* 30 133 U
    0.000078* 0.00198* 30 133 V
    0.00012 0.0030* 30 133 N
    0.000156259 0.0039* 30 133 P
    0.00024 0.0060* 50 222 K
    0.0003125 0.0079* 50 222 A
    0.00048 0.0121* 50 222 J
    0.0005 0.0127 50 222 3
    0.000625 0.0158* 50 222 B
    0.00096 0.0243* 50 222 Q
    0.00098 0.025 50 222 AQ
    0.00125 0.0317* 50 222 C
    0.00192 0.0487* 50 222 R
    *Values truncated 
  • Specifications - 1.8° Double Stack (Rotary) +


    Series
    35M4-V
    Stack Length
    Double
    Wiring Units Bipolar
    Step Angle degree 1.8°
    Winding voltage VDC 2.33  5 12 
    Current/Phase A rms 2  0.91 0.38
    Resistance/Phase ohms (Ω) 1.2  5.5 31.6
    Inductance/Phase mH 1.95  7.63 65.1
    Power Input Watts 9.1
    Standard motors are Class B rated for a maximum temperature of 130°C (155°C for Class F)

    Linear Travel / Step
    Load Limit
    Order Code I.D.
    inches mm lbs n
    0.00006 0.0015* 30 133 U
    0.000078* 0.00198* 30 133 V
    0.00012 0.0030* 30 133 N
    0.000156259 0.0039* 30 133 P
    0.00024 0.0060* 50 222 K
    0.0003125 0.0079* 50 222 A
    0.00048 0.0121* 50 222 J
    0.0005 0.0127 50 222 3
    0.000625 0.0158* 50 222 B
    0.00096 0.0243* 50 222 Q
    0.00098 0.025 50 222 AQ
    0.00125 0.0317* 50 222 C
    0.00192 0.0487* 50 222 R
    *Values truncated 
  • Specifications - 0.9° Double Stack (Rotary) +


    Series
    35P4-V
    Stack Length
    Double
    Wiring Units Bipolar
    Step Angle degree 0.9°
    Winding voltage VDC 2.33  5 12 
    Current/Phase A rms 2  0.91 0.38
    Resistance/Phase ohms (Ω) 1.2  5.5 31.6
    Inductance/Phase mH 1.95  7.63 65.1
    Power Input Watts 9.1
    Standard motors are Class B rated for a maximum temperature of 130°C (155°C for Class F)

    Linear Travel / Step
    Load Limit
    Order Code I.D.
    inches mm lbs n
    0.00006 0.0015* 30 133 U
    0.000078* 0.00198* 30 133 V
    0.00012 0.0030* 30 133 N
    0.000156259 0.0039* 30 133 P
    0.00024 0.0060* 50 222 K
    0.0003125 0.0079* 50 222 A
    0.00048 0.0121* 50 222 J
    0.0005 0.0127 50 222 3
    0.000625 0.0158* 50 222 B
    0.00096 0.0243* 50 222 Q
    0.00098 0.025 50 222 AQ
    0.00125 0.0317* 50 222 C
    0.00192 0.0487* 50 222 R
    *Values truncated 
  • Dimensional Drawings +


  • Performance Curves +


    TORQUE vs PULSE RATE: Rotary Function
    Bipolar, 100% Duty Cycle



    35000 Series Linear Actuator Curves
    35000 Series Single Stack 1.8° and 0.9° degree curves in Hybrid Linear Actuators  
    35000 Series Double Stack 1.8° degree curves in Hybrid Linear Actuators

    NOTE:  All chopper drive curves were created with a 5 volt motor and a 40 volt power supply.

    Ramping can increase the performance of a motor either by increasing the top speed or getting a heavier load accelerated up to speed faster.  Also, deceleration can be used to stop the motor without overshoot.

    With L/R drives peak force and speeds are reduced, using a unipolar drive will yield a further 30% force reduction.
  • Wiring Diagram and Stepping Sequence +


    Hybrid Wiring
    Stepping Sequence- Hybrid Linear Actuator

    Bipolar Q2-Q3 Q1-Q4 Q6-Q7 Q5-Q8
    Unipolar Q1 Q2 Q3 Q4
    Step . . . .
    1 ON OFF ON OFF
    2 OFF ON ON OFF
    3 OFF ON OFF ON
    4 ON OFF OFF ON
    1 ON OFF ON OFF
  • Part Number Guide +





    EXAMPLE: 
    LR35KH4AB-05-910 = Dual motion, 35000 Series (Size 14, 1.5-in, 35 mm sq.) 0.9° rotary, 1.8° linear, bipolar coils, .00048-in (0.0121 mm), 5 Volts DC, 1-in (26 mm) Stroke