AmetekHaydonKerk AmetekAMS

AC Synchronous - Rotary

36000 Series Haydon Rotary Can Stack Stepper Motor
Stepping motors can also be run on AC (Alternating Current).  However, one phase must be energized through a properly selected capacitor.  In this case the motor is limited to only one synchronous speed.  For instance, if 60 hertz is being supplied, there are 120 reversals or alterations of the power source.  The phase being energized by a capacitor is also producing the same number of alterations at an offset time sequence.  The motor is really being energized at the equivalent of 240 steps per second.
  • Specifications +


      Rotary Speed
    (RPMs) @
     Torque     Capacitor @
      Coil Resistance
    (Ohms)
    Motor Part No.
    60 Hz
    50 Hz
    (oz-in) (N-cm) Watts Amps
    60 Hz
    50 Hz
    Connection
    Diagram

     Main Wind
    Cap. Wind
    Z20540-24-700
    600 500 0.5 0.4 2.5 .15 12.5 12.5 2 300 75
    A26440-24 300 250 0.9 0.6 3.4 .20 15.0 15.0 2 214 54
    A265540-24 600 500 0.9 0.6 3.4 .20 15.0 20.0 2 214 54
    Z26440-24-700 300 250 1.2 0.8 3.4 .19 15.0 15.0 2 214 54
    Z26540-24-700 600 500 1.5 1.1 3.4 .19 15.0 15.0 2 214 54
    A36240-24 150 125 2.5 1.8 4.6 .23 20.0 20.0 2 160 40
    A36440-24 300 250 2.6 1.8 4.6 .23 20.0 20.0 2 160 40
    A36540-24 600 500 1.3 0.9 4.6 .23 20.0 20.0 2 160 40
    A46440-24 300 250 8.5 6.0 10.0 .38 20.0 20.0 1 29 29
    A46540-24 600 500 6.5 4.6 10.0 .38 20.0 25.0 1 58 58
    A36240-120 150 125 2.5 1.8 4.6 .05 0.8 0.8 2 4000 1000
    A36440-120 300 250 2.6 1.8 4.6 .05 0.8 0.8 2 4000 1000
    A36540-120 600 500 1.3 0.9 4.6 .05 0.8 0.8 2 4000 1000
    A46440-120 300 250 8.5 6.0 10.0 .08 0.8 0.8 1 725 725
    A46540-120 600 500 6.5 4.6 10.0 .08 0.8 1.0 1 1450 1450




  • Wiring Diagram +



    AC Synchronous Rotary Wiring
  • Part Number Guide +



    AC Synchronous Rotary PN